<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>15358</ErrorNumber>
<ErrorFamily>Autoloader</ErrorFamily>
<ErrorMessage>
ALE: STEP : axis 1 timed out while aborting
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Trendsetter_400/800_Proofing</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<OperatorAction>
<DescriptionText><text>
This error should not occur during normal machine operation. If it does,
first select the RESUME button on the workstation dialog box.  If that
does not correct the problem, select RESET TRENDSETTER
from the workstation TRENDSETTER pull-down menu. If the problem persists,
call Creo Service.
</text></DescriptionText>
</OperatorAction>
<ServiceInformation>
<DescriptionText><text>
Make sure that the red ABORT button is not pressed and type "resume".  If
the procedure described in Operator Action does not correct the problem, then
"reset" the recorder.
</text></DescriptionText>
</ServiceInformation>
<Cause>
This error occurs if the stepper motor, while running, either takes longer
than five seconds to stop after the red ABORT button is pressed, or the
"vr abort" or "abort" diagnostic monitor commands are issued. This error
should not occur during normal machine operation.
</Cause>
<SeeAlso>
<UnnumberedList>
<Link><LinkAddress>../error_messages/22074.xml</LinkAddress><LinkTitle>E_ALE_STEP_ABORTED</LinkTitle></Link>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:33:04 2008 PST
</Updated>
<Links>
</Links>
</Error>